Centrifugal fan is a mechanical device for moving air or other gases in a direction at an angle to the incoming fluid. Centrifugal fans often contain a ducted housing to direct outgoing air in a specific direction or across a heat sink.
These fans increase the speed and volume of an air stream with the rotating impellers.
Use of Ambient condition for Centrifugal Fan: |
|
Temperature(°C): |
ball bearing:(B)-20°C~60°C |
|
|
|
|
|
|
|
|
Voltage |
AC single-phase:230±10% ; AC three-phase:400±10% |
|
|
|
Vibration |
50/60Hz |
|
|
|
Ingress protection: |
IP20/IP4 |
|
|
|
Insulation Class: |
Class "B","F","H" is available in three options |
|
|
|
Useful life |
The Laboratory temperature at 25°C,the ball bearing can be lasted 50000hours |
(Special temperature can be customized, the highest temperature can be up to-40°C~100°C)
Technical parameters :
Model No: |
Rated Voltage |
Freqency |
Rated Current |
Rated Power |
Speed |
Capacitor |
Max.Air Flow |
Noise |
Static Pressure |
|
(VAC) |
(Hz) |
(A) |
(W) |
(RPM) |
(uf) |
(m³/h) |
(CFM) |
(dB) |
(Pa) |
TXF214S-133LX2 |
230 |
50/60 |
1.0/1.3 |
180/220 |
1350/1550 |
5/630 |
930/820 |
547.4/482.6 |
55/59 |
435/460 |
TXF214S-133LX3 |
380 |
50 |
0.3 |
100 |
1350 |
/ |
930 |
547.4 |
56 |
435 |
TXF214S-133LX4 |
440 |
50 |
0.3 |
100 |
1350 |
/ |
930 |
547.4 |
56 |
435 |
PACKAGE:
WORKSHOP: